title: "I do not see a \"Go\" button with the TR-1 or TR-1P"
description: The TR-1 and TR-1P expects to detect a load. If there is an open in the circuit, the Go button will not be present.
---

[Skip to content](https://support.raytechusa.com/migration/i-do-not-see-a-go-button-with-the-tr-1-or-tr-1p#main-content)

English

Show submenu for translations

![249401-Raytech USA logo_red edit.jpg\]](https://support.raytechusa.com/hs-fs/hubfs/249401-Raytech%20USA%20logo_red%20edit.jpg?height=40&name=249401-Raytech%20USA%20logo_red%20edit.jpg)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- Go to www.raytechusa.com

 Go to www.raytechusa.com

 Let's find a Solution.

- There are no suggestions because the search field is empty.

1. [Raytech USA Help Center](https://support.raytechusa.com/migration?hsLang=en)
2. [Single Phase & Three Phase Ratiometers](https://support.raytechusa.com/migration/single-phase-three-phase-ratiometers?hsLang=en)
3. [TR-1](https://support.raytechusa.com/migration/single-phase-three-phase-ratiometers?hsLang=en#tr-1)

# I do not see a "Go" button with the TR-1 or TR-1P

## The TR-1 and TR-1P expects to detect a load. If there is an open in the circuit, the Go button will not be present.

The system may have detected an open in the circuit on either the high side or low side of the transformer. To verify the system and/or test leads, connect H1 to X1 and H0 to X0. If properly connected, the Go will appear on the screen.

Note, the system must detect the presence of a load to show the GO button.

 

- [Frequently Asked Questions](https://support.raytechusa.com/migration/frequently-asked-questions?hsLang=en)
- [Capacitance / Dissipation Factor / Power Factor](https://support.raytechusa.com/migration/capacitance-dissipation-factor-power-factor?hsLang=en)
- [Low Resistance](https://support.raytechusa.com/migration/low-resistance?hsLang=en#main-content)
  
  
  
  
  
    - [Micro Centurion II (MC2)](https://support.raytechusa.com/migration/low-resistance?hsLang=en#micro-centurion-ii-mc2)
    - [Kelvin Spike Probes](https://support.raytechusa.com/migration/low-resistance?hsLang=en#kelvin-spike-probes)
- [mini-ATOS](https://support.raytechusa.com/migration/mini-atos?hsLang=en)
- [Single Phase & Three Phase Ratiometers](https://support.raytechusa.com/migration/single-phase-three-phase-ratiometers?hsLang=en#main-content)
  
  
  
  
  
    - [TR-Mark III 250V](https://support.raytechusa.com/migration/single-phase-three-phase-ratiometers?hsLang=en#tr-mark-iii-250v)
    - [TR-1](https://support.raytechusa.com/migration/single-phase-three-phase-ratiometers?hsLang=en#tr-1)
    - [General](https://support.raytechusa.com/migration/single-phase-three-phase-ratiometers?hsLang=en#general)
- [Winding Resistance](https://support.raytechusa.com/migration/winding-resistance?hsLang=en)

[![Chill listening crop-3](https://support.raytechusa.com/hs-fs/hubfs/249401-Raytech%20USA%20logo_red%20edit.jpg?width=66&height=24&name=249401-Raytech%20USA%20logo_red%20edit.jpg "Chill listening crop-3")](http://www.raytechusa.com)

Raytech USA Help Center

Copyright © 2026, Raytech USA